The settings available in the rigid matching panels allow fine-tuning the basic procedure in a multitude of ways. While there are successful settings (as the predefined ones), experimenting with these configurations may result in improved or faster matches in specific situations.
Basic Parameters
Smoothing |
A Gaussian filter with configurable width in mm or pixels can be separately enabled for the Reference and the Reslice study. While this introduces an additional performance burden during start-up, iterations are less likely to get trapped in a local optimum with smoothed images. |
Dissimilarity |
This is the main definition of the matching algorithm. Note that a short explanation of the selected dissimilarity function can be shown with the ? button besides the selection. The selections are
|
Interpolation method |
Type of interpolation used during reslicing. Has an impact on speed, and may also influence convergence. |
Sample rate |
Density of resampling the original images during the matching process. Coarse sampling increases speed dramatically, but too coarse images may not allow any more for accurate matching. 6 or 8 mm is often satisfactory for MRI/PET matching. A strategy with multiple searches can be implemented in combination with the Algorithm runs option: the first matching runs are performed at a coarse resolution, but the last one with a fine sampling rate for an accurate final match. |
Minimization Method |
Powell usually finds the optimal match faster than Downhill Simplex. |
Function tolerance |
Termination criterion for the iterations. |
Reference Mask |
Allows defining a mask for the reference image if none was created and/or set to the matching protocol after the reference image was loaded. To discard the mask activate the Clear file or directory button |
Input Mask |
Allows defining a mask for the input image if none was created and/or set to the matching protocol after the input image was loaded. To discard the mask activate the Clear file or directory button |
Save |
Save the parameter settings for later use. |
Calculate Inverse Transformation |
If the box is checked, the inverse transformation is also calculated once the matching completed. |
Advanced Parameters
Thresholding method |
The image volume considered during matching can be restricted to a sub-volume by thresholding, eg. by excluding the image background. Absolute values can be defined when User defined option is selected as thresholding method. |
Normalize values to (0,1) |
When this box is checked, the image values are normalized to the numeric range [0,1]. Note that the operation is a scaling, not a binarization of the image. This transformation may be required when applying one of difference criteria, if the dynamic range of the matched images is different for instance because of different administered tracer doses. |
Algorithm runs |
A value > 1 configures multiple successive matching runs, whereby a run is started with the result parameters of the preceding run. |
Max iterations |
A maximal number of optimization steps can be configured to avoid "endless" looping. |
Scale |
If box is checked allows scaling the image during rigid matching |
No rotation |
If box is checked no rotation is performed during the automatic rigid matching. |